We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

This study was conducted to assess the performance of the Abbott laboratories LCx HCV RNA Quantitative Assay (LCx assay) in the clinical setting. Four clinical laboratories measured LCx assay precision, specificity, and linearity. In addition, a method comparison was conducted between the LCx assay and the Roche HCV Amplicor Monitor, version 2.0 (Roche Monitor 2.0) and the Bayer VERSANT HCV RNA 3.0 Assay (Bayer bDNA 3.0) quantitative assays. For precision, the observed LCx assay intra-assay standard deviation (S.D.) was 0.060-0.117 log IU/ml, the inter-assay S.D. was 0.083-0.133 log IU/ml, the inter-lot S.D. was 0.105-0.177 log IU/ml, the inter-site S.D. was 0.099-0.190 log IU/ml, and the total S.D. was 0.113-0.190 log IU/ml. The specificity of the LCx assay was 99.4% (542/545; 95% CI, 98.4-99.9%). For linearity, the mean pooled LCx assay results were linear (r=0.994) over the range of the panel (2.54-5.15 log IU/ml). A method comparison demonstrated a correlation coefficient of 0.881 between the LCx assay and Roche Monitor 2.0, 0.872 between the LCx assay and Bayer bDNA 3.0, and 0.870 between Roche Monitor 2.0 and Bayer bDNA 3.0. The mean LCx assay result was 0.04 log IU/ml (95% CI, -0.08, 0.01) lower than the mean Roche Monitor 2.0 result, but 0.57 log IU/ml (95% CI, 0.53, 0.61) higher than the mean Bayer bDNA 3.0 result. The mean Roche Monitor 2.0 result was 0.60 log IU/ml (95% CI, 0.56, 0.65) higher than the mean Bayer bDNA 3.0 result. The LCx assay quantitated genotypes 1-4 with statistical equivalency. The vast majority (98.9%, 278/281) of paired LCx assay-Roche Monitor 2.0 specimen results were within 1 log IU/ml. Similarly, 86.6% (240/277) of paired LCx assay and Bayer bDNA 3.0 specimen results were within 1 log, as were 85.6% (237/277) of paired Roche Monitor 2.0 and Bayer specimen results. These data demonstrate that the LCx assay may be used for quantitation of HCV RNA in HCV-infected individuals.

Original publication

DOI

10.1016/j.jviromet.2004.09.020

Type

Journal article

Journal

J Virol Methods

Publication Date

02/2005

Volume

123

Pages

171 - 178

Keywords

DNA, Viral, Genotype, Hepacivirus, Humans, Immunoenzyme Techniques, RNA, Viral, Reference Standards, Reverse Transcriptase Polymerase Chain Reaction, Sensitivity and Specificity, Viremia, Virology